200A latch relay
latch relay
Features
-Latching relay-200A switching capability-Accord with ANSI C 12.1 (Carrying:10kA; Suitching: 12kA peak, 12kA RMS short circuit current)-Switching power up to 55.4kVA-4kV dielectric strength (between coil and contacts)-Environmental friendly product (RoHS compliant)-Outline Dimensions: (73.3 x 74.8 x 29.5) mm
CONTACT DATA
Contact arrangement | 2A, 2B |
Contact resistence | 2m (at 1A 24VDC) |
Contact material | AgSnO2 |
Contact rating (Res. load) | 200A 277VAC128VDC |
Max. switching voltage | 440VAC |
Max. switching current | 200A |
Max. switching power | 55400VA 1 5600W |
Mechanical endurance | 5 x 104 OPS |
Electrical endurance | 6 x 103 OPS |
CHARACTERISTICS
Insulation resistance |
1000M (at 500VDC) | ||
Dielectric strength | Between coil & contacts | 4000VAC 1min | |
Between open contacts | 2000VAC 1min | ||
Creepage distance | 9.6mm | ||
Operate time (at nomi. volt.) | 20ms max. | ||
Release time (at nomi. volt.) | 20ms max. | ||
Shock resistance | Functional | 98m1s2 | |
Destructive | 980m1s2 | ||
Vibration resistance | 10Hz to 55Hz 1.5mm DA | ||
Humidity | 5% to 98% RH, 40 | ||
Ambient temperature | -40 to 85 | ||
Termination | PCB & QC | ||
Unit weight | 400g | ||
Construction | Dust protected |
COIL
Coil power :Single Coil: 12W; Double Coil: 24W
COIL DATA
Nominal Voltage VDC | Pick-up Voltage VDC | Pulse Duration ms |
Coil Resistance x (1 10%) | |
12 |
9.6 |
200 |
Singl Coil | 12 |
24 |
19.2 |
200 | 48 | |
48 |
38.4 |
200 | 190 | |
12 |
9.6 |
200 |
Double Coil | 6+6 |
24 |
19.2 |
200 | 24+24 | |
48 |
38.4 |
200 | 95+95 |
Notes: When requiring other nominal voltage, special order allowed
NOTICE
1. Relay is on the reset or set status when being released from stock, with the consideration of shock risen from transit and relay mounting, relay would be changed to set or reset status, therefore, when application ( connecting the power supply), please reset the relay to set or reset status on request.
2. In order to maintain set or reset status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than set or reset time. Do not energize voltage to set coil and reset coil simultaneously. And also long energized time (more than 1min) should be avoided.
3. The terminals of relay without twisted copper wire can not be tin- soldered, can not be moved willfully, more over two terminals can not be fixed at the same time.
200A latch relay